THIS IS A GLOBAR HEATED, FULL MUFFLE ATMOSPHERE FURNACE . PARTS ARE LOADED ON TO A 12″ WIDE MESH BELT. PARTS PASS THOUGH A 12′ LONG HEAT SECTION AND THEN PASS THOUGH 26′ OF WATER JACKETED COOLING. PARTS ARE THEN UNLOADED ON A 2.5′ LONG UNLOAD TABLE. GLOBAR HEATING ELEMENTS ARE LOCATED ABOVE AND BELOW THE ALLOY MUFFLE. A VARIABLE SPEED DRIVE MOVES THE BELT THROUGH THE FURNACE AT RATES 1 – 10 INCHES PER MINUTE ( CAN BE CHANGED ). A FLAME CURTAIN ON THE ENTRANCE VESTIBULE AND FIBER GLASS CURTAINS AT THE EXIT VESTIBULE PROTECT THE INTERGITY OF THE ATMOSPHERE.
July 2012
26